Skip to content
LauréoBetaPublic procurement intelligence
Settings
My account

TABLES D'OPÉRATION UNIVERSELLES & LAMPES DE CHIRURGIE (LED) DE TYPE DOUBLE TÊTE

Source: SEAO

Centre intégré universitaire de santé et de services sociaux du Saguenay - Lac-Saint-Jean (Hôpital de Chicoutimi) · Method not published · closed November 10, 2010 at 2:00 p.m., Quebec time

Facts

Published
October 22, 2010
Method
0
Time to submit
19 days · computed between publication and closing
how it's calculated — Time to submit

Time to submit — where the number comes from

The calculation
Days between publication (October 22, 2010) and closing (November 10, 2010), rounded to the day: 19 days.
What goes in
The source publishes no duration for this notice: the number comes from its two dates. A gap of less than half a day, or a closing before publication, gives no window.
Source
SEAO — Quebec open data · CC-BY 4.0 · data up to date as of October 4, 2026 · link to this detail
Value
— not declared
Reference
Notice no. 3138
UNSPSC
42295112Tables d’opération
SEAO category
G21 — Fourniture et équipement médicaux et produits pharmaceutiques

SEAO, Données Québec · data as of October 4, 2026

Description

100%

Veuillez prendre note que la date d'ouverture des soumissions est reportée au 10 novembre 2010 à 14h00.

Read more — 1,726 charactersShow less

(Information ajoutée le 2 novembre 2010) Pour être admis à soumissionner, un Soumissionnaire doit avoir, au Québec ou dans un territoire visé par un Accord Intergouvernemental applicable, un Bureau d’affaires où il exerce ses activités de façon permanente, clairement identifié à son nom et accessible durant les heures normales de bureau Le DONNEUR D’ORDRE désire faire l’acquisition de trois (3) tables d’opération universelles ainsi que trois (3) lampes de chirurgie (LED) de type double tête pour son service du bloc opératoire. A. Tables d’opération universelles Spécifications minimales : Ø Base mobile sur roues avec freins Ø Capacité supportée minimale de 400 kg Ø Mouvement de la table entièrement motorisé Ø Contrôle des mouvements à l’aide d’une pédale et d’une télécommande Ø Possibilité de pré-programmer des positions Ø Possibilité d’arrêter le mouvement en tout temps Ø Inclinaison Trendelenburg de 25° Ø Inclinaison Trendelenburg inversé de 25° Ø Inclinaison latérale de +/- 20° Ø Hauteur minimale ne doit pas être supérieure à 75 cm Ø Surface des sections entre les rails doit être radio transparente Ø Minimum de 4 sections motorisées et cousinées Ø Section des jambes Ø Pieds amovible B. Lampes de chirurgie (LED) de type double tête Spécifications minimales : Ø Taille du champ d’au moins 16 cm de diamètre; Ø Distance focale d’au moins 65 cm ; Ø Illumination minimale de 80 000 Lux; Ø Indice de rendu des couleurs (IRC) de 93 ou équivalent; Ø Température de couleur 4000 K; Ø Ajustement vertical d’au moins 80 cm ; Ø Poignées stérilisables; Ø Durée de vie DEL d’au moins 10 000 heures. Ø Le système d'ancrage devra être de type à montage central. Le croquis d’ancrage doit être annexé au présent document.

SEAO, Données Québec · data as of October 4, 2026

Precedents — this code at this buyer

Where do these figures come from?
reserved · subscriptionViews used up for this month: this block opens with an account.

Bidders

the source is silent — The open dataset publishes bidders together with the outcome. No outcome published in the open dataset, more than a year after the closing date.

The price to beat

the source is silent — The open dataset publishes no submitted amount for this public tender.

Contracting authority history — most recent awards

Where do these figures come from?
reserved · subscriptionViews used up for this month: this block opens with an account. Free with an account

Award

the source is silent — No signed contract published in the open dataset, more than a year after the closing date.

Documents

the source is silent — No document in the open dataset · SEAO notice

Similar open notices

widened to class 422951
how it's counted — Similar notices — how the list is built

Similar notices — how the list is built — where the number comes from

The calculation
No open notice under 42295112: same UNSPSC class (422951), and still open.
What goes in
Other tender notices still open under the same code, whatever the organisation. This selection of still-open notices covers SEAO. Unverified CanadaBuys deadlines are excluded; federal notices remain available in search.
Source
SEAO — Quebec open data · CC-BY 4.0 · data up to date as of October 4, 2026 · link to this detail

SEAO, Données Québec · data as of October 4, 2026

Cite this page
Permalink
https://www.laureo.ca/en/avis/ocds-ec9k95-463522
Citation
Lauréo, “TABLES D'OPÉRATION UNIVERSELLES & LAMPES DE CHIRURGIE (LED) DE TYPE DOUBLE TÊTE”, Centre intégré universitaire de santé et de services sociaux du Saguenay - Lac-Saint-Jean (Hôpital de Chicoutimi), notice no. 3138, data as of October 4, 2026, from SEAO / Données Québec (CC-BY 4.0). https://www.laureo.ca/en/avis/ocds-ec9k95-463522
Reuse
Figures and text reusable with attribution. SEAO documents are never redistributed: they are linked to their official source.
Report an error